Associated productsMixing Valve Control Pack

The UFCM control pack is designed to supply temperature controlled hot water to the underfloor heating system. The control pack is pre-fabricated so it can be easily attached to a manifold (supplied separately) that has 210mm centres.

  • Key design information
  • Features and benefits

Additional information

Medium

water or glycol solution

Maximum glycol percentage

30%

Maximum working pressure

10 bar

Maximum working temperature

90°C

Adjustable control temperature range

20 to 64°C

Pre-set temperature

MIN (20°C)

Finish

Nickel plated

Thread connections

BS EN ISO 228-1

Kvvalue

3.2 m3/hr (Dp= 1 bar: Tmix= 42)